Customer Reviews

BW MCX3-XW00-Y-NA GasAlertMicroClip X3 Multi-Gas Detector, 2 Gas %LEL, O2

Model: MCX3-XW00-Y-NA

BW MCX3-XW00-Y-NA GasAlertMicroClip X3 Multi-Gas Detector, 2 Gas %LEL, O2-


Downloads: datasheet

BW MCX3-XW00-Y-NA GasAlertMicroClip X3 Multi-Gas Detector, 2 Gas %LEL, O2

Model: MCX3-XW00-Y-NA

Simple one button operation minimizes the need for training and gets workers on the job faster. Extended 18 hour battery run time keeps workers safe for longer. Beeping alone while working in a loud environment might not always be enough but with the visible flashing green IntelliFlash™ workers are notified of the dangers. With a new oxygen sensor that extends overall operational life expectancy. Yellow Housing

Simple one button operation minimizes the need for training and gets workers on the job faster. Extended 18 hour battery run time keeps workers safe for longer. Beeping alone while working in a loud environment might not always be enough but with the visible flashing green IntelliFlash™ workers are notified of the dangers. With a new oxygen sensor that extends overall operational life expectancy. Yellow Housing

Sale Price $529.76 CAD
Regular Price $616.00 CAD
Availability 2 to 3 Weeks
Quantity

Add In-House ISO Certified Calibration to your MCX3-XW00-Y-NA

Add In-House ISO Certified Calibration to your MCX3-XW00-Y-NA


BW GasAlert MicroClip X3 Series Offers

The easy to wear, slim and compact GasAlertMicroClip X3 provides affordable protection from atmospheric gas hazards and extended battery life, especially in cold weather. The GasAlertMicroClip X3 features visual compliance at a glance with the flashing, green IntelliFlash™. Easy one-button operation reduces training time and lets workers focus on the job at hand. For simple, cost-effective management of your records, calibration and bump testing, choose BW's MicroDock II automatic test and calibration system and Fleet Manager II software.

Meets ACGIH 1 ppm H2S TWA recommendations.


Features

  • Oxygen Sensor with an 3 Year Warranty
  • Designed for cold weather performance
  • IP68 rating which protects from total dust ingress and from immersion over 1m
  • IntelliFlash verifies operation and compliance to both the user and supervisor
  • Built-in datalogging & event logging
  • Tamper-proof, one button operation
  • Powered by a rechargeable lithium polymer battery
  • Continuous LCD shows real-time gas concentrations
  • Compact and lightweight design makes it comfortable to wear
  • Water-resistant
  • Simple automatic calibration procedure; compatible with BW MicroDock II automatic test and calibration station
  • Full function self-test of sensor, battery status, circuit integrity and audible/visual alarms on start up
  • Bright wide-angled visual alarm bars
  • Equipped with internal vibrating alarm for high noise areas
  • Built-in concussion-proof boot
  • Multi-language support in English, French, German, Spanish and Portuguese
  • Conveniently manage your fleet using Fleet Manager II

Supported Gases

  • H2S
  • CO
  • O2
  • LEL

Software

Data storage and analysis has never been so simple. With the same look and feel as Fleet Manager, Fleet Manager II allows users to download information directly from BW instruments or the MicroDock II.

With improved functionality, users can:

  • Automatically create accurate and user-friendly reports
  • Easily sort, format and graph data as well as view history
  • Archive and share data easily, including databases
  • Download and manage calibration and bump check records as well as datalogged information onto any PC

BW GasAlert MicroClip X3 Specifications

Gas Measuring Range Resolution
H2S 0 to 100 ppm 1 ppm
CO 0 to 500 ppm 1 ppm
O2 0 to 30.0% 0.1%
Combustible gases 0 to 100% LEL
0 to 5.0% v/v
1%
0.1%
Alarm setpoints for all sensors are user adjustable. Setpoints are automatically displayed during instrument start up.
Size 4.4 x 2.4 x 1.2 in / 11.3 x 6.0 x 3.1 cm
Weight 6.7 oz. / 190 g
Temperature -4 to 122°F / -20 to 50°C
Humidity 0% to 95% RH (non-condensing)
Alarms - Visual, vibrating, audible (95 dB)
- Low, high, STEL, TWA, OL (over limit)
Tests Audible/visual alarms on activation, sensors, battery and circuitry (continuous)
Typical Battery Life 18 hours; recharges in less than 6 hours
User Options Confidence beep
Set STEL interval
Sensor on/off
Latching alarms
Safe display mode
Stealth mode
Calibration lock
Auto zero on start up
O2 auto calibration on start up
Set bump test interval
Force bump test when overdue
Ratings EMI/RFI: Complies with EMC Directive 2004/108/EC IP 66
Certifications and Approvals Class I, Div. 1, Gr. A, B, C, D
ATEX: II 1 G
Ex ia IIC T4 Ga
IECEx: Ex ia IIC T4 Ga
European Conformity
Warranty Three-year warranty on Oxygen Sensor, full two-year warranty on all other sensors
Click here for complete specifications on the BW MCX3-XW00-Y-NA

Whats included with the BW GasAlert MicroClip X3

  • Detector complete with specified sensor(s), stainless steel alligator clip, and concussion-proof housing
  • Rechargeable Battery
  • Wall Outlet Charging Adaptor
  • Calibration/Test Cap and Hose
  • Manual
  • Multi-language CD manual

How to Select the Right Gas Detection Solution

by Don Galman

There are many gas detection products on the market that might appear to be the same, but a closer inspection of specification, functionality and features reveals major differences in what products can do and the potential value they can offer. Similarly, individual applications are also unique in their respective designs, needs and processes undertaken.

Know your site risks

Before beginning to consider gas detection equipment, a risk assessment needs to be conducted. Any company employing staff has the obligation to conduct risk assessments to identify potential hazards and these can include potential gas, vapor or Oxygen deficiency risks. If gas hazards are identified, gas detection is applicable as a risk reduction method.

Identifying the prime objective

Depending on the processes being undertaken and the gases being detected, remote or off-site alarm notification plus event data logging/reporting may also be required for Health and Safety management records. Another factor impacting on the need for enhanced reporting functions might be regulatory compliance or a condition of insurance.

Ask the right questions

Having identified the primary objective, the suitable equipment is selected by asking a number of key questions. These fall into three broad categories:

  • The gases to be detected and where they may come from
  • The location and environmental conditions where detection is to take place
  • The ease of use for operators and routine servicing personnel
Identify the gases to be detected and where they may come from

The gases to be detected should be identified by the risk assessment, however experienced gas detection equipment manufacturers and their approved distributors are often able to help in this process, based on their experience of similar applications. However, it is important to remember that it is the end-user’s responsibility to identify all potential hazards. It is also essential to identify the potential source of a gas release as this helps determine the number and location of detectors required for a fixed gas detection system.

Consider the environmental conditions

The performance, accuracy and reliability of any gas detection equipment will be affected by the environmental conditions it is subjected to. Temperature, humidity and pressure levels at the location all have a direct bearing on the type of equipment that should be selected. Additional factors such as potential variations resulting from a production process itself, diurnal/nocturnal fluctuations and seasonal changes may also affect the type of device which is suitable.

Understand product functionality

The next area of consideration relates to additional product functionality. Aspects like wiring configuration are important, especially when retro-fitting into an existing application. If the apparatus is being integrated into a separate safety system, certain communication protocols may also be required such as HART®, Lonworks or Modbus®. Consideration will also need to be given regarding the requirement for local displays on transmitter units and local configuration of the unit and gas displays may also be a useful addition.

Measure the ease of use for operators and routine servicing personnel

Routine maintenance is another important consideration. Some gases and vapors can be detected with a number of different sensing technologies, e.g. Hydrocarbon gases with catalytic beads or Non-dispersive Infrared NDIR. Catalytic beads do not provide fail-to-safety operation and therefore can require a high frequency of routine maintenance, however NDIR based solutions tend to have a higher initial purchase price, but may require less routine maintenance. In-house resource to undertake such routine maintenance needs to be identified and in the absence of such a resource, budgeting for third party maintenance is an important factor in selecting the right equipment.


Need Help Selecting the Right Solution?

If you have questions about any of our gas detection products or services, please don’t hesitate to contact us. Whether you need a hand finding a new product or need help with your current system, just ask our team of Factory Trained Experts.


comments powered by Disqus

How to: Calibrate a BW Gas Detector

How to: Bump Test a BW Gas Detector

Meet Shauna Park: Our Gas Detection Expert

Click on a category to view a selection of compatible accessories with the BW MCX3-XW00-Y-NA GasAlertMicroClip X3 Multi-Gas Detector, 2 Gas %LEL, O2.

BW REG-0.5 Calibration Gas Regulator for GasAlert, 0.5 LPM, Male REG-0.5
Calibration gas regulator at 0.5 LPM for all GasAlert gas detectors. Regulators are used to ensure you receive the required flow of calibration gas for your application.




BW MK-CG2-58 Wall Mount for 34, 58, 103 L Gas Cylinders, Red MK-CG2-58
Note: Gas cylinder not included




BW REG-DF-1 Demand Flow Regulator for GasAlert REG-DF-1
Demand flow regulator for all GasAlert gas detectors. Demand flow regulators are recommended since they deliver the required gas flow rate automatically. Demand flow regulators must be used with gas detectors with internal or external sample draw pumps.




BW C2-HOSE1-1 Calibration Hose, Tygon, 1ft (0.3m) C2-HOSE1-1
Tygon calibration hose (1ft. / 0.3m)




BW CG-Q34-4 Quad Gas Calibration Gas, CH4, O2, H2S, CO, 34L CG-Q34-4
CH4 (2.5%), O2 (18.0%), H2S (25 ppm), and CO (100 ppm) gas contained within a 34L, aluminum cylinder. Fully compatible with BW Technologies gas detectors requiring specified cal gas mixture.




BW CG-Q58-4 Quad Gas Calibration Gas, CH4, O2, H2S, CO, 58L CG-Q58-4
CH4 (2.5%), O2 (18.0%), H2S (25 ppm), and CO (100 ppm) gas contained within a 58L, aluminum cylinder. Fully compatible with BW Technologies gas detectors requiring specified cal gas mixture.




BW MC2-C01-MC5 Multi-Unit Cradle Charger for GasAlertMicroClip XT, 5-Units MC2-C01-MC5
Using adaptors other than those supplied may cause damage to GasAlertMicroClip XT units in the charger. Charging status can be monitored on the detectors' LCD. Wall or table mountable, the multi-unit charger ships with a power adaptor. Simply slide detectors or batteries into the charger and wait for the battery icon on the LCD to show the battery is fully charged or the LED on the battery to turn green.
Note: Units not included.




BW GA-PA-3 12-24 VDC Direct-Wire Power Adaptor for GasAlert XT, XT II & Quattro, V DC GA-PA-3
For use with the GasAlert XT, XT II & Quattro. Connect directly to a 12V or 24V power system with the 12-24 V DC Direct-Wire Power Adaptor. Simply connect the adaptor to the detector's charging/IR interface.




BW GA-VPA-1 Vehicle Power Adaptor for GasAlertMicroClip XT & XL, GasAlertQuattro & GasAlertMax XT II GA-VPA-1
Vehicle power adaptor, compatible with GasAlert Micro Clip XT and XL, GasAlert Quattro, and GasAlert Max XT II models.




BW GA-PA-1-NA Replacement Power Adaptor for GasAlert GA-PA-1-NA
GA-PA-1-NA BW Technologies 120VAC North America Replacement Power Adapter / Charger.





BW SR-X3P Replacement Sensor for GasAlertMicroClip X3, O2, 3 Year SR-X3P
Replacement oxygen (O2) sensors make gas detector maintenance easy. For use with the BW GasAlertMicroClip X3 series of BW gas detectors.
Note: This sensor includes a 3 year warranty from BW Technologies.




BW DOCK2-2-1P-00-G MicroDock II Automatic Test & Calibration Station with GasAlertMicroClip Docking Module, Charging with No Power Supply DOCK2-2-1P-00-G
Manage the calibration and bump testing on your portable gas detector in the most cost effective way, sort through the data collected and charge your units. Automated testing and calibrating system, automated management of event logs, calibration logs, etc and automated verification of alarm set points allows you to keep working without missing a notification.




BW DOCK2-2-1C1P-00-G MicroDock II Automatic Test & Calibration Station with GasAlertMicroClip Docking Module, Charging with Power Supply DOCK2-2-1C1P-00-G
Manage the calibration and bump testing on your portable gas detector in the most cost effective way, sort through the data collected and charge your units. Automated testing and calibrating system, automated management of event logs, calibration logs, etc and automated verification of alarm set points allows you to keep working without missing a notification.




BW DOCK2-0-1P-00-G GasAlertMicroClip XT module for MicroDock II Automatic Test & Calibration Station, charging with no power supply and 2 inlets DOCK2-0-1P-00-G
Plug the GasAlertMicroClip XT docking module into the MicroDock II Automatic Test & Calibration Station and start managing it.




BW DOCK2-2-1C1P-00-G GasAlertMicroClip XT module for MicroDock II Automatic Test & Calibration Station, Charging with power supply and 2 inlets DOCK2-0-1C1P-00-G
Plug the GasAlertMicroClip XT docking module into the MicroDock II Automatic Test & Calibration Station and start managing it.




BW GA-CH-2 Chest Harness for GasAlert GA-CH-2
For use with GasAlert gas detectors.
Note: Unit not included.








BW GA-LY-1 Short Strap for GasAlert, 6in (15.2cm) GA-LY-1
The short strap (6 in. / 15.2 cm) facilitates the attachment of your gas detector to your clothing or personal protective equipment (PPE). The smaller loop attaches to buttons or other fasteners.





BW SR-W-MC-DUM Dummy Sensor for Combustible Sensor Location for GasAlertMicroClip XT & GasAlertMax XT II, LEL SR-W-MC-DUM
Dummy sensor for combustible (LEL) sensor locations. Please note that this sensor has no detection abilities and will not put the unit into alarm. It is only for training or long term storage of a unit.




BW SR-TOX-MC-DUM Dummy Sensor for Toxic Sensor Locations for GasAlertMicroClip XT & GasAlertMaxXT II SR-TOX-MC-DUM
Dummy sensor for toxic sensor locations. Please note that this sensor has no detection abilities and will not put the unit into alarm. It is only for training or long term storage of a unit.




BW SR-DUMM1 Dummy Sensor for Oxygen Sensor Location for GasAlertMicroClip XT, O2 SR-DUMM1
Dummy sensor for oxygen (O2) sensor location for GasAlertMicroClip XT series of BW gas detectors. Please note that this sensor has no detection abilities and will not put the unit into alarm. It is only for training or long term storage of a unit.




BW SR-H-MC Replacement MICROceL Hydrogen Sulfide Sensor for GasAlert MicroClip XT & GasAlert Max XT II, H2 SR-H-MC
Replacement MICROceL hydrogen sulfide (H2S) sensor for the GasAlert MicroClip XT or GasAlert Max XT II series of BW gas detectors.




BW SR-M-MC Replacement MICROceL Carbon Monoxide Sensor for GasAlert MicroClip XT & GasAlert Max XT II, CO SR-M-MC
Replacement MICROceL carbon monoxide (CO) sensor for the GasAlert MicroClip XT or GasAlert Max XT II series of BW gas detectors.




BW SR-W-MP75C Replacement MICROpeL Combustible Sensor For GasAlert Detectors, LEL SR-W-MP75C
Replacement MICROpeL combustible (LEL) sensor for the GasAlertMicroClip XT or GasAlertMax XT II series of BW gas detectors.




BW MC-CK-DL GasAlertMicroClip Deluxe Confined Space Kit MC-CK-DL
Use the Confined Space Kit with a BW GasAlert Gas Detector to detect gas in tight spaces. The included IR Connectivity Kit can be used to transmit data from the Gas Detector to a PC. The included Regulator can be used to control the flow of gas at up to 0.5 liters per minute (LPM).
Detector, calibration gas and motorized sampling pump sold separately.




BW MC-CK-CC Carrying Case for GasAlertMicroClip XT MC-CK-CC
BW MC-CK-CC Carrying Case for use with the GasAlertMicroClip XT, with foam and lid insert from confined space kit. Dimensions: 18 x 13 x 6".
Note: Detector, calibration gas and motorized sampling pump sold separately.




Customer Reviews for the BW MCX3-XW00-Y-NA

Ask a question about BW MCX3-XW00-Y-NA GasAlertMicroClip X3 Multi-Gas Detector, 2 Gas %LEL, O2

comments powered by Disqus

BW GasAlert MicroClip X3 Series Offers

The easy to wear, slim and compact GasAlertMicroClip X3 provides affordable protection from atmospheric gas hazards and extended battery life, especially in cold weather. The GasAlertMicroClip X3 features visual compliance at a glance with the flashing, green IntelliFlash™. Easy one-button operation reduces training time and lets workers focus on the job at hand. For simple, cost-effective management of your records, calibration and bump testing, choose BW's MicroDock II automatic test and calibration system and Fleet Manager II software.

Meets ACGIH 1 ppm H2S TWA recommendations.


Features

  • Oxygen Sensor with an 3 Year Warranty
  • Designed for cold weather performance
  • IP68 rating which protects from total dust ingress and from immersion over 1m
  • IntelliFlash verifies operation and compliance to both the user and supervisor
  • Built-in datalogging & event logging
  • Tamper-proof, one button operation
  • Powered by a rechargeable lithium polymer battery
  • Continuous LCD shows real-time gas concentrations
  • Compact and lightweight design makes it comfortable to wear
  • Water-resistant
  • Simple automatic calibration procedure; compatible with BW MicroDock II automatic test and calibration station
  • Full function self-test of sensor, battery status, circuit integrity and audible/visual alarms on start up
  • Bright wide-angled visual alarm bars
  • Equipped with internal vibrating alarm for high noise areas
  • Built-in concussion-proof boot
  • Multi-language support in English, French, German, Spanish and Portuguese
  • Conveniently manage your fleet using Fleet Manager II

Supported Gases

  • H2S
  • CO
  • O2
  • LEL

Software

Data storage and analysis has never been so simple. With the same look and feel as Fleet Manager, Fleet Manager II allows users to download information directly from BW instruments or the MicroDock II.

With improved functionality, users can:

  • Automatically create accurate and user-friendly reports
  • Easily sort, format and graph data as well as view history
  • Archive and share data easily, including databases
  • Download and manage calibration and bump check records as well as datalogged information onto any PC

BW GasAlert MicroClip X3 Specifications

Gas Measuring Range Resolution
H2S 0 to 100 ppm 1 ppm
CO 0 to 500 ppm 1 ppm
O2 0 to 30.0% 0.1%
Combustible gases 0 to 100% LEL
0 to 5.0% v/v
1%
0.1%
Alarm setpoints for all sensors are user adjustable. Setpoints are automatically displayed during instrument start up.
Size 4.4 x 2.4 x 1.2 in / 11.3 x 6.0 x 3.1 cm
Weight 6.7 oz. / 190 g
Temperature -4 to 122°F / -20 to 50°C
Humidity 0% to 95% RH (non-condensing)
Alarms - Visual, vibrating, audible (95 dB)
- Low, high, STEL, TWA, OL (over limit)
Tests Audible/visual alarms on activation, sensors, battery and circuitry (continuous)
Typical Battery Life 18 hours; recharges in less than 6 hours
User Options Confidence beep
Set STEL interval
Sensor on/off
Latching alarms
Safe display mode
Stealth mode
Calibration lock
Auto zero on start up
O2 auto calibration on start up
Set bump test interval
Force bump test when overdue
Ratings EMI/RFI: Complies with EMC Directive 2004/108/EC IP 66
Certifications and Approvals Class I, Div. 1, Gr. A, B, C, D
ATEX: II 1 G
Ex ia IIC T4 Ga
IECEx: Ex ia IIC T4 Ga
European Conformity
Warranty Three-year warranty on Oxygen Sensor, full two-year warranty on all other sensors
Click here for complete specifications on the BW MCX3-XW00-Y-NA

Whats included with the BW GasAlert MicroClip X3

  • Detector complete with specified sensor(s), stainless steel alligator clip, and concussion-proof housing
  • Rechargeable Battery
  • Wall Outlet Charging Adaptor
  • Calibration/Test Cap and Hose
  • Manual
  • Multi-language CD manual

How to Select the Right Gas Detection Solution

by Don Galman

There are many gas detection products on the market that might appear to be the same, but a closer inspection of specification, functionality and features reveals major differences in what products can do and the potential value they can offer. Similarly, individual applications are also unique in their respective designs, needs and processes undertaken.

Know your site risks

Before beginning to consider gas detection equipment, a risk assessment needs to be conducted. Any company employing staff has the obligation to conduct risk assessments to identify potential hazards and these can include potential gas, vapor or Oxygen deficiency risks. If gas hazards are identified, gas detection is applicable as a risk reduction method.

Identifying the prime objective

Depending on the processes being undertaken and the gases being detected, remote or off-site alarm notification plus event data logging/reporting may also be required for Health and Safety management records. Another factor impacting on the need for enhanced reporting functions might be regulatory compliance or a condition of insurance.

Ask the right questions

Having identified the primary objective, the suitable equipment is selected by asking a number of key questions. These fall into three broad categories:

  • The gases to be detected and where they may come from
  • The location and environmental conditions where detection is to take place
  • The ease of use for operators and routine servicing personnel
Identify the gases to be detected and where they may come from

The gases to be detected should be identified by the risk assessment, however experienced gas detection equipment manufacturers and their approved distributors are often able to help in this process, based on their experience of similar applications. However, it is important to remember that it is the end-user’s responsibility to identify all potential hazards. It is also essential to identify the potential source of a gas release as this helps determine the number and location of detectors required for a fixed gas detection system.

Consider the environmental conditions

The performance, accuracy and reliability of any gas detection equipment will be affected by the environmental conditions it is subjected to. Temperature, humidity and pressure levels at the location all have a direct bearing on the type of equipment that should be selected. Additional factors such as potential variations resulting from a production process itself, diurnal/nocturnal fluctuations and seasonal changes may also affect the type of device which is suitable.

Understand product functionality

The next area of consideration relates to additional product functionality. Aspects like wiring configuration are important, especially when retro-fitting into an existing application. If the apparatus is being integrated into a separate safety system, certain communication protocols may also be required such as HART®, Lonworks or Modbus®. Consideration will also need to be given regarding the requirement for local displays on transmitter units and local configuration of the unit and gas displays may also be a useful addition.

Measure the ease of use for operators and routine servicing personnel

Routine maintenance is another important consideration. Some gases and vapors can be detected with a number of different sensing technologies, e.g. Hydrocarbon gases with catalytic beads or Non-dispersive Infrared NDIR. Catalytic beads do not provide fail-to-safety operation and therefore can require a high frequency of routine maintenance, however NDIR based solutions tend to have a higher initial purchase price, but may require less routine maintenance. In-house resource to undertake such routine maintenance needs to be identified and in the absence of such a resource, budgeting for third party maintenance is an important factor in selecting the right equipment.


Need Help Selecting the Right Solution?

If you have questions about any of our gas detection products or services, please don’t hesitate to contact us. Whether you need a hand finding a new product or need help with your current system, just ask our team of Factory Trained Experts.


comments powered by Disqus

How to: Calibrate a BW Gas Detector

How to: Bump Test a BW Gas Detector

Meet Shauna Park: Our Gas Detection Expert

Click on a category to view a selection of compatible accessories with the BW MCX3-XW00-Y-NA GasAlertMicroClip X3 Multi-Gas Detector, 2 Gas %LEL, O2.

BW REG-0.5 Calibration Gas Regulator for GasAlert, 0.5 LPM, Male REG-0.5
Calibration gas regulator at 0.5 LPM for all GasAlert gas detectors. Regulators are used to ensure you receive the required flow of calibration gas for your application.




BW MK-CG2-58 Wall Mount for 34, 58, 103 L Gas Cylinders, Red MK-CG2-58
Note: Gas cylinder not included




BW REG-DF-1 Demand Flow Regulator for GasAlert REG-DF-1
Demand flow regulator for all GasAlert gas detectors. Demand flow regulators are recommended since they deliver the required gas flow rate automatically. Demand flow regulators must be used with gas detectors with internal or external sample draw pumps.




BW C2-HOSE1-1 Calibration Hose, Tygon, 1ft (0.3m) C2-HOSE1-1
Tygon calibration hose (1ft. / 0.3m)




BW CG-Q34-4 Quad Gas Calibration Gas, CH4, O2, H2S, CO, 34L CG-Q34-4
CH4 (2.5%), O2 (18.0%), H2S (25 ppm), and CO (100 ppm) gas contained within a 34L, aluminum cylinder. Fully compatible with BW Technologies gas detectors requiring specified cal gas mixture.




BW CG-Q58-4 Quad Gas Calibration Gas, CH4, O2, H2S, CO, 58L CG-Q58-4
CH4 (2.5%), O2 (18.0%), H2S (25 ppm), and CO (100 ppm) gas contained within a 58L, aluminum cylinder. Fully compatible with BW Technologies gas detectors requiring specified cal gas mixture.




BW MC2-C01-MC5 Multi-Unit Cradle Charger for GasAlertMicroClip XT, 5-Units MC2-C01-MC5
Using adaptors other than those supplied may cause damage to GasAlertMicroClip XT units in the charger. Charging status can be monitored on the detectors' LCD. Wall or table mountable, the multi-unit charger ships with a power adaptor. Simply slide detectors or batteries into the charger and wait for the battery icon on the LCD to show the battery is fully charged or the LED on the battery to turn green.
Note: Units not included.




BW GA-PA-3 12-24 VDC Direct-Wire Power Adaptor for GasAlert XT, XT II & Quattro, V DC GA-PA-3
For use with the GasAlert XT, XT II & Quattro. Connect directly to a 12V or 24V power system with the 12-24 V DC Direct-Wire Power Adaptor. Simply connect the adaptor to the detector's charging/IR interface.




BW GA-VPA-1 Vehicle Power Adaptor for GasAlertMicroClip XT & XL, GasAlertQuattro & GasAlertMax XT II GA-VPA-1
Vehicle power adaptor, compatible with GasAlert Micro Clip XT and XL, GasAlert Quattro, and GasAlert Max XT II models.




BW GA-PA-1-NA Replacement Power Adaptor for GasAlert GA-PA-1-NA
GA-PA-1-NA BW Technologies 120VAC North America Replacement Power Adapter / Charger.





BW SR-X3P Replacement Sensor for GasAlertMicroClip X3, O2, 3 Year SR-X3P
Replacement oxygen (O2) sensors make gas detector maintenance easy. For use with the BW GasAlertMicroClip X3 series of BW gas detectors.
Note: This sensor includes a 3 year warranty from BW Technologies.




BW DOCK2-2-1P-00-G MicroDock II Automatic Test & Calibration Station with GasAlertMicroClip Docking Module, Charging with No Power Supply DOCK2-2-1P-00-G
Manage the calibration and bump testing on your portable gas detector in the most cost effective way, sort through the data collected and charge your units. Automated testing and calibrating system, automated management of event logs, calibration logs, etc and automated verification of alarm set points allows you to keep working without missing a notification.




BW DOCK2-2-1C1P-00-G MicroDock II Automatic Test & Calibration Station with GasAlertMicroClip Docking Module, Charging with Power Supply DOCK2-2-1C1P-00-G
Manage the calibration and bump testing on your portable gas detector in the most cost effective way, sort through the data collected and charge your units. Automated testing and calibrating system, automated management of event logs, calibration logs, etc and automated verification of alarm set points allows you to keep working without missing a notification.




BW DOCK2-0-1P-00-G GasAlertMicroClip XT module for MicroDock II Automatic Test & Calibration Station, charging with no power supply and 2 inlets DOCK2-0-1P-00-G
Plug the GasAlertMicroClip XT docking module into the MicroDock II Automatic Test & Calibration Station and start managing it.




BW DOCK2-2-1C1P-00-G GasAlertMicroClip XT module for MicroDock II Automatic Test & Calibration Station, Charging with power supply and 2 inlets DOCK2-0-1C1P-00-G
Plug the GasAlertMicroClip XT docking module into the MicroDock II Automatic Test & Calibration Station and start managing it.




BW GA-CH-2 Chest Harness for GasAlert GA-CH-2
For use with GasAlert gas detectors.
Note: Unit not included.








BW GA-LY-1 Short Strap for GasAlert, 6in (15.2cm) GA-LY-1
The short strap (6 in. / 15.2 cm) facilitates the attachment of your gas detector to your clothing or personal protective equipment (PPE). The smaller loop attaches to buttons or other fasteners.





BW SR-W-MC-DUM Dummy Sensor for Combustible Sensor Location for GasAlertMicroClip XT & GasAlertMax XT II, LEL SR-W-MC-DUM
Dummy sensor for combustible (LEL) sensor locations. Please note that this sensor has no detection abilities and will not put the unit into alarm. It is only for training or long term storage of a unit.




BW SR-TOX-MC-DUM Dummy Sensor for Toxic Sensor Locations for GasAlertMicroClip XT & GasAlertMaxXT II SR-TOX-MC-DUM
Dummy sensor for toxic sensor locations. Please note that this sensor has no detection abilities and will not put the unit into alarm. It is only for training or long term storage of a unit.




BW SR-DUMM1 Dummy Sensor for Oxygen Sensor Location for GasAlertMicroClip XT, O2 SR-DUMM1
Dummy sensor for oxygen (O2) sensor location for GasAlertMicroClip XT series of BW gas detectors. Please note that this sensor has no detection abilities and will not put the unit into alarm. It is only for training or long term storage of a unit.




BW SR-H-MC Replacement MICROceL Hydrogen Sulfide Sensor for GasAlert MicroClip XT & GasAlert Max XT II, H2 SR-H-MC
Replacement MICROceL hydrogen sulfide (H2S) sensor for the GasAlert MicroClip XT or GasAlert Max XT II series of BW gas detectors.




BW SR-M-MC Replacement MICROceL Carbon Monoxide Sensor for GasAlert MicroClip XT & GasAlert Max XT II, CO SR-M-MC
Replacement MICROceL carbon monoxide (CO) sensor for the GasAlert MicroClip XT or GasAlert Max XT II series of BW gas detectors.




BW SR-W-MP75C Replacement MICROpeL Combustible Sensor For GasAlert Detectors, LEL SR-W-MP75C
Replacement MICROpeL combustible (LEL) sensor for the GasAlertMicroClip XT or GasAlertMax XT II series of BW gas detectors.




BW MC-CK-DL GasAlertMicroClip Deluxe Confined Space Kit MC-CK-DL
Use the Confined Space Kit with a BW GasAlert Gas Detector to detect gas in tight spaces. The included IR Connectivity Kit can be used to transmit data from the Gas Detector to a PC. The included Regulator can be used to control the flow of gas at up to 0.5 liters per minute (LPM).
Detector, calibration gas and motorized sampling pump sold separately.




BW MC-CK-CC Carrying Case for GasAlertMicroClip XT MC-CK-CC
BW MC-CK-CC Carrying Case for use with the GasAlertMicroClip XT, with foam and lid insert from confined space kit. Dimensions: 18 x 13 x 6".
Note: Detector, calibration gas and motorized sampling pump sold separately.




Ask a question about BW MCX3-XW00-Y-NA GasAlertMicroClip X3 Multi-Gas Detector, 2 Gas %LEL, O2

Customer Reviews for the BW MCX3-XW00-Y-NA

More BW Products

Find the right sensor with our sensor selection tool